playfield_transfers:
This is a config file reference. Click for instructions.
This page is reference material which explains every setting and option for this section of an MPF yaml config file. See the instructions for config files for formatting and other details. See our guide to config file examples for more examples of real configs in action.
Valid in | |
---|---|
machine config files | YES |
mode config files | NO |
The playfield_transfers:
section of your config is where you configure
devices which transfer balls between
playfields.
This is an example:
switches:
s_transfer:
number:
playfield_transfers:
transfer1:
ball_switch: s_transfer
captures_from: playfield1
eject_target: playfield2
transfer2:
transfer_events: transfer_ball
captures_from: playfield1
eject_target: playfield2
playfields:
playfield1:
label: Playfield 1
default_source_device: None
playfield2:
label: Playfield 2
default_source_device: None
Required settings
The following sections are required in the playfield_transfers:
section of your config:
captures_from:
Single value, type: string name of a ball_devices: device. Defaults to empty.
Source playfield for the transfer.
eject_target:
Single value, type: string name of a ball_devices: device. Defaults to empty.
Target playfield for the transfer.
Optional settings
The following sections are optional in the playfield_transfers:
section of your config. (If you don't include them, the default will be
used).
ball_switch:
Single value, type: string name of a switches: device. Defaults to empty.
Ball switch which triggers the transfer.
transfer_events:
List of one (or more) device control events (Instructions for entering device control events). Defaults to empty.
Default: None
Events in this list, when posted, will trigger a ball transfer.
console_log:
Single value, type: one of the following options: none, basic, full.
Default: basic
Log level for the console log for this device.
debug:
Single value, type: boolean
(true
/false
). Default: false
Set this to true to see more debug output.
file_log:
Single value, type: one of the following options: none, basic, full.
Default: basic
Log level for the file log for this device.
label:
Single value, type: string
. Default: %
Name in service mode.
tags:
List of one (or more) values, each is a type: string
. Defaults to
empty.
Tags of the device. Not used currently.
Related How To guides
Something missing or wrong? You can fix it!
This website is edited by people like you! Is something wrong or missing? Is something out of date, or can you explain it better?
Please help us! You can fix it yourself and be an official "open source" contributor!
It's easy! See our Beginner's guide to editing the docs.
Page navigation via the keyboard: < >
You can navigate this site via the keyboard. There are two modes:
General navigation, when search is not focused:
- F , S , / : open search dialog
- P , , : go to previous page
- N , . : go to next page
While using the search function:
- Down , Up : select next / previous result
- Esc , Tab : close search
- Enter : go to highlighted page in the results