coil_player:
This is a config file reference. Click for instructions.
This page is reference material which explains every setting and option for this section of an MPF yaml config file. See the instructions for config files for formatting and other details. See our guide to config file examples for more examples of real configs in action.
Valid in | |
---|---|
machine config files | YES |
mode config files | YES |
Note
This section can also be used in a show file in the coils:
section of
a step.
The coil_player:
section of your config is where you configure
coil/solenoid/driver actions (pulse, enable, disable, etc.) based on
events. It's also used in shows (via the coils:
section) to perform
coil actions in that show step.
Example from a config file:
coil_player:
some_event: coil_1
some_other_event:
coil_2:
action: enable
hold_power: .5
In the example above, when the event called some_event
is posted,
coil_1 will pulse. When the event some_other_event
is posted, coil_2
will enable (be held on) at power level 0.5 (means 50% of maximum
power).
Note that the some_event: coil_1
is entered in a different way than
the some_other_event:
. The first one has a simple key/value pair,
whereas the second has a complete nested sub-configuration.
The first example shows the "express" config, while the second shows the full config. (What's an "express config?" Details here.
The coil player's express config is the "pulse" action.
Example coil player from a show:
##! show: test
- time: 0
coils:
coil1: pulse
See Coil player for details.
Optional settings
The following sections are optional in the coil_player:
section of
your config. (If you don't include them, the default will be used).
action:
Single value, type: one of the following options: pulse, on, off,
enable, disable. Default: pulse
What action the coil should perform. Note that "on" and "enable" are the same, and that "disable" and "off" are the same.
hold_power:
Single value, type: number
(will be converted to floating point).
Defaults to empty.
This setting lets you control how much power is sent to the coil when
it's "held" in the on position. This is an float value from 0-1 (i.e.
0% power to 100% power) which controls the relative power. If not set it
will use default_hold_power
of the coils:.
max_wait_ms:
Single value, type: integer
. Defaults to empty.
The maximum time in ms which MPF might use to delay this pulse for power management reasons. See Power Management in Software for details.
pulse_ms:
Single value, type: integer
. Defaults to empty.
The number of milliseconds you'd like this coil to pulse for. This
setting overrides the coil's default_pulse_ms setting. Note that this
setting only affects pulse actions. Make sure you are not exceeding the
coil's max_pulse_ms setting. If not set it will use
default_pulse_ms
of the coils:.
pulse_power:
Single value, type: number
(will be converted to floating point).
Defaults to empty.
The power factor which controls how much power is applied during the initial pulse phase of the coil's activation. (Note that not all hardware platforms support variable pulse power.)
If not set it will use default_pulse_power
of the
coils:.
Related How To guides
Something missing or wrong? You can fix it!
This website is edited by people like you! Is something wrong or missing? Is something out of date, or can you explain it better?
Please help us! You can fix it yourself and be an official "open source" contributor!
It's easy! See our Beginner's guide to editing the docs.
Page navigation via the keyboard: < >
You can navigate this site via the keyboard. There are two modes:
General navigation, when search is not focused:
- F , S , / : open search dialog
- P , , : go to previous page
- N , . : go to next page
While using the search function:
- Down , Up : select next / previous result
- Esc , Tab : close search
- Enter : go to highlighted page in the results