sequences:
This is a config file reference. Click for instructions.
This page is reference material which explains every setting and option for this section of an MPF yaml config file. See the instructions for config files for formatting and other details. See our guide to config file examples for more examples of real configs in action.
Valid in | |
---|---|
machine config files | YES |
mode config files | YES |
See also sequences.
The structure of sequence logic blocks is like this:
sequences:
the_name_of_this_logic_block:
<settings>
some_other_logic_block:
<settings>
a_third_logic_block:
<settings>
Note that the actual name of the logic block doesn't really matter. Mainly they're just used in the logs.
Required settings
The following sections are required in the sequences:
section of your
config:
events:
List of one (or more) events. The device will add handlers for those events. Defaults to empty.
The events section of a sequence logic block is where you define the events this logic block will watch for in order to make progress towards completion.
The real power of logic blocks is that you can enter more than one event for each step, and only one of the of the events of that step has to happen for that step to be complete.
Another way to look at it is that there's an AND THEN between all the steps. For the Sequence to complete, you need Step 1 AND THEN Step 2 AND THEN Step 3. But since you can enter more than one event for each step, you could think of those like ORs. So you have Step 1 (event1 OR event2) AND THEN Step 2 (event3) AND THEN Step 3 (event4 OR event5), like this:
##! mode: mode1
sequences:
my_sequence:
events:
- event1, event2
- event3
- event4, event5
It might seem kind of confusing at first, but you can build this up bit-by-bit and figure them out as you go along.
You can enter anything you want for your events, whether it's one of MPF's built-in events or a made-up event that another logic block posts when it completes. (This is how you chain multiple logic blocks together to form complex logic.)
For example:
##! mode: mode1
sequences:
logic_block_1:
events:
- event1
- event2
- event3
- event4
- event5
events_when_complete: logic_block_1_done
logic_block_2:
events:
- event1, event2, event3
- event4
- event5
events_when_complete: logic_block_2_done
In the example above, there are two logic blocks. The first one just has five steps that need to complete (in 1-2-3-4-5 exact order since we're dealing with sequence logic blocks), and each step only has one event that will mark is as complete.
In the second example, if event 1, 2, or 3 is posted, that will count for step 1, and then both events 4 and 5 need to be posted for steps 2 and 3. (Again, in order, so event 1, 2, or 3 has to be posted before the logic block will even start looking for event 4.)
So in the second one, you could get event2, event4, then event5 posted, for example, and that will lead to logic_block_2_done being posted.
Note that you can have two logic blocks with the same events at the same time, and MPF will track the state of each logic block separately.
Optional settings
The following sections are optional in the sequences:
section of your
config. (If you don't include them, the default will be used).
console_log:
Single value, type: one of the following options: none, basic, full.
Default: basic
Log level for the console log for this device.
debug:
Single value, type: boolean
(true
/false
). Default: false
Set this to true to see additional debug output. This might impact the performance of MPF.
file_log:
Single value, type: one of the following options: none, basic, full.
Default: basic
Log level for the file log for this device.
label:
Single value, type: string
. Default: %
Name of this device in service mode.
tags:
List of one (or more) values, each is a type: string
. Defaults to
empty.
Currently unused.
Optional settings
The following sections are optional in the logic_blocks_common:
section of your config. (If you don't include them, the default will be
used).
disable_events:
List of one (or more) device control events (Instructions for entering device control events).
Event(s) that will disable this logic block.
A logic block must be enabled to track hits, progress, and to post events.
disable_on_complete:
Single value, type: boolean
(true
/false
). Default: true
True/False (or Yes/No) which controls whether this logic block disables itself once it completes. This does not reset the current value.
enable_events:
List of one (or more) device control events (Instructions for entering device control events).
Event(s) that will enable this logic block.
A logic block must be enabled to track hits, progress, and to post events.
If you don't have any enable_events listed, then the logic block will automatically be enabled when the player's ball starts.
events_when_complete:
List of one (or more) events.
Events that will be posted when this device is completed.
events_when_hit:
List of one (or more) events.
Events that will be posted when this device is hit or advanced.
persist_state:
Single value, type: boolean
(true
/false
). Default: false
Boolean setting (yes/no or true/false) which controls whether this logic
block remembers where it was from ball-to-ball. If False
, then this
logic block will reset itself whenever a new ball starts. If True
,
then this logic block will be saved to the player variable
(logic_block_name)_state.
Note that logic block state is reset on mode end when this is False
and, as normal modes stop at the end of a ball, the state is always
maintained on a per-player basis, regardless of what this setting is
configured for.
reset_events:
List of one (or more) device control events (Instructions for entering device control events).
Event(s) that will reset this logic block back to its original value. This has no effect on the enabled/disabled state of the block.
Note that there are also reset_on_complete:
and persist_state:
settings which also affect how and when the logic block is reset.
You can reset a logic block regardless of whether it's enabled.
reset_on_complete:
Single value, type: boolean
(true
/false
). Default: true
True/False (or Yes/No) which controls whether this logic block resets itself once it completes. This just resets the current value or progress. It does not change the enabled or disabled state.
Note, disable_on_complete
default is true
, which may seem like reset
isn't working. For something like a counter that automatically starts
again change disable_on_complete
to false
.
restart_events:
List of one (or more) device control events (Instructions for entering device control events).
List of one (or more) events which, when posted, will restart this logic block. A restart is a reset, then an enable, combined into a single action.
start_enabled:
Single value, type: boolean
(true
/false
).
If true
this device will start enabled. If false
this device will
start disabled. If you omit this the device will start enabled unless
you specify enable_events
in which case the device will start
disabled.
Related How To guides
Something missing or wrong? You can fix it!
This website is edited by people like you! Is something wrong or missing? Is something out of date, or can you explain it better?
Please help us! You can fix it yourself and be an official "open source" contributor!
It's easy! See our Beginner's guide to editing the docs.
Page navigation via the keyboard: < >
You can navigate this site via the keyboard. There are two modes:
General navigation, when search is not focused:
- F , S , / : open search dialog
- P , , : go to previous page
- N , . : go to next page
While using the search function:
- Down , Up : select next / previous result
- Esc , Tab : close search
- Enter : go to highlighted page in the results