Skip to content

Classic Two-Coil (one switch)

Related Config File Sections:

This guide will show you how to configure MPF to use an older-style drain and trough combination that uses two coils (one to eject the ball from the drain hole and a second to release a ball into the plunger lane).

This guide is written for the types of devices that have only have one switch on the trough side, like this example of a Gottlieb System 3 machine (Brooks 'n Dunn):

image

If your trough system has multiple switches in the trough (one for each ball), then use this guide instead.

In the types of troughs this guide is for, a ball ejected from the drain over the hump into the trough will only momentarily activate the trough switch as the ball rolls by, unless the trough is full, in which case the last ball that goes into it sits on the switch.

The following diagram shows a more clear view of the type of trough system this guide is for: (This is a side view)

image

1. Add the switches

The first step is to add all the switches to the switches: section of your config file. Create an entry in your switches: section for the drain switch as well as each switch in your trough, like this: (This example has three switches in the trough. Yours may have more or less.)

switches:
  s_drain:
    number: 1
  s_trough_enter:
    number: 2

Note that we configured this switches with numbers 01 and 02, but you should use the actual switch numbers for your control system that the switches are connected to. (See How to configure "number:" settings for instructions for each type of control system.)

It makes no difference what the actual switch names are. We use s_drain and s_trough_entry, though you can call them whatever you want.

2. Add the coils

Next, create the entries in your coils: section for the drain eject coil and the trough release coil. Again, the names don't matter. We'll call them c_drain_eject and c_trough_release and enter them like this:

coils:
  c_drain_eject:
    number: 3
    default_pulse_ms: 20
  c_trough_release:
    number: 4
    default_pulse_ms: 20

Again, the number: entries in your config will vary depending on your actual hardware, and again, you can pick whatever name you want for your coil.

You'll also note that we went ahead and entered default_pulse_ms: values of 20 which will override the default pulse times of 10ms. It's hard to say at this point what values you'll actually need. You can always adjust this at any time. You can play with the exact values in a bit once we finish getting everything set up.

Note that some trough coils use a shorter pulse to pop the ball into the plunger lane. However, some machines have gates or rotational devices that need to be active for much longer. However, if the pulse time is over about 50ms, then that coil should be enabled with PWM and disabled versus pulsed, so in that case, you also need to add default_pulse_power: which tells MPF it's ok to enable this coil (with 25% hold power in this case).

In other words, a trough with long release time would look like this:

coils:
  c_trough_release:
    number: 4
    default_pulse_ms: 20ms
    default_hold_power: 0.25

3. Add your "drain" ball device

In MPF, anything that holds and releases a ball is a ball device. With this drain/trough setup, there are actually two ball devices---one for the drain and a second for the trough.

Let's add the drain device first, which we'll add to the ball_devices: section of your machine config. (If you don't have that section add it now.)

Then in your ball_devices: section, create an entry called bd_drain:, like this:

ball_devices:
    bd_drain:

This means that you're creating a ball device called bd_drain. We use the preface bd_ to indicate that this is a ball device which makes it easier when we're referencing them later. Then under your bd_drain: entry, you'll start entering the configuration settings for your drain ball device.

  • Add ball_switches: s_drain which means this device will use the s_drain switch to know whether or not this device has a ball.
  • Add eject_coil: c_drain_eject which is the name of the coil that will eject the ball from the drain.
  • Add eject_targets: bd_trough which tells MPF that this ball device ejects its balls into the device called bd_trough. (We'll create that device in the next step.)
  • Add tags: drain which tells MPF that balls entering this device mean that a ball has drained from the playfield.
  • Set eject_timeouts to the maximum time the ball can take to return if the eject fails.

Your drain device configuration should look now look like this:

#! switches:
#!   s_drain:
#!     number: 1
#!   s_trough_enter:
#!     number: 2
#! coils:
#!   c_drain_eject:
#!     number: 3
#!     default_pulse_ms: 20
#!   c_trough_release:
#!     number: 4
#!     default_pulse_ms: 20
ball_devices:
  bd_drain:
    ball_switches: s_drain
    eject_coil: c_drain_eject
    eject_targets: bd_trough
    tags: drain
    eject_timeouts: 4s
#!   bd_trough:
#!     entrance_switch: s_trough_enter
#!     entrance_switch_full_timeout: 500ms
#!     ball_capacity: 3
#!     eject_coil: c_trough_release
#!     tags: trough, home
#!     eject_timeouts: 3s

4. Add your "trough" ball device

Next create a second entry in the ball_devices: section called bd_trough that will be for the trough device that holds the balls that are ejected from the drain before they're released into the plunger lane.

The configuration is pretty straightforward:

  • Add entrance_switch: s_trough_enter which tells MPF which switch is used as the "entrance" switch to this device. (An entrance switch is the switch that's momentarily activated as balls enter this device.)
  • Add entrance_switch_full_timeout: 500ms which tells MPF that if the entrance switch stays active for more than this amount of time, that means that this device is full.
  • Add ball_capacity: 3 (or whatever the number of balls is that can be stored on the trough side). This tells MPF how many balls are in this device when a ball is sitting on the entrance switch.
  • Add eject_coil: c_trough_release which is the name of the coil that will be pulsed to eject the ball from the drain.
  • Add eject_targets: bd_plunger_lane which tells MPF that this ball device ejects its balls into the device called bd_plunger_lane. (We won't actually create the plunger device in this How To guide, but you need to have it, so see the Plungers & Ball Launch Devices documentation for full details since there are lots of different types of plungers.
  • Add tags: home, trough which tells MPF that it's ok to store unused balls here and that it's ok for balls to be here when games start.

Your trough device configuration should look now look like this:

#! switches:
#!   s_drain:
#!     number: 01
#!   s_trough_enter:
#!     number: 02
#!   s_plunger:
#!     number: 10
#! coils:
#!   c_drain_eject:
#!     number: 03
#!     default_pulse_ms: 20
#!   c_trough_release:
#!     number: 04
#!     default_pulse_ms: 20
ball_devices:
#!   bd_drain:
#!     ball_switches: s_drain
#!     eject_coil: c_drain_eject
#!     eject_targets: bd_trough
#!     tags: drain
#!     eject_timeouts: 4s
  bd_trough:
    entrance_switch: s_trough_enter
    entrance_switch_full_timeout: 500ms
    ball_capacity: 3
    eject_coil: c_trough_release
    eject_targets: bd_plunger_lane
    tags: trough, home
    eject_timeouts: 3s
#!   bd_plunger_lane:
#!     ball_switches: s_plunger
#!     mechanical_eject: true
#!     eject_timeouts: 5s

If you need to enable c_trough_release for 1s (more than a few ms) it would look like this:

#! switches:
#!   s_drain:
#!     number: 01
#!   s_trough_enter:
#!     number: 02
#!   s_plunger:
#!     number: 10
#! coils:
#!   c_drain_eject:
#!     number: 03
#!     default_pulse_ms: 20
#!   c_trough_release:
#!     number: 04
#!     default_pulse_ms: 20
ball_devices:
#!   bd_drain:
#!     ball_switches: s_drain
#!     eject_coil: c_drain_eject
#!     eject_targets: bd_trough
#!     tags: drain
#!     eject_timeouts: 4s
  bd_trough:
    entrance_switch: s_trough_enter
    entrance_switch_full_timeout: 500ms
    ball_capacity: 3
    eject_coil: c_trough_release
    eject_coil_enable_time: 100ms
    eject_targets: bd_plunger_lane
    tags: trough, home
    eject_timeouts: 3s
#!   bd_plunger_lane:
#!     ball_switches: s_plunger
#!     mechanical_eject: true
#!     eject_timeouts: 5s

5. Configure the balls installed

One of the downsides of only having one switch in the trough is that if that switch is not active, then MPF doesn't actually know how many balls are in it. (In the example diagram at the beginning of this guide where the trough can hold three balls, if that trough entry switch is not active, then there could be zero, 1, or 2 balls in the trough.)

MPF is able to keep track of how many balls are in the trough by tracking balls entered versus balls released. However when MPF starts up, if that entrance switch isn't active, then it won't know how many balls are there.

There's a setting in the machine config called machine:balls_installed: that tells MPF how many actual balls are installed in the machine. So when MPF starts, it can count up all the balls in all the devices and see if they're all there or if any are missing. Since that's a bit tricky with the single switch in the trough, you telling MPF how many total balls are installed in the machine help it know what to do if that entrance switch isn't active when MPF starts up.

Here's an example from the machine config:

machine:
  balls_installed: 4

6. Configure your virtual hardware to start with balls in the trough

While we're talking about the trough, it's probably a good idea to configure MPF so that when you start it in virtual mode (with no physical hardware) that it starts with the trough full of balls. To do this, add a new section to your config file called virtual_platform_start_active_switches:. (Sorry this entry name is hilariously long.) As its name implies, virtual_platform_start_active_switches: lets you list the names of switches that you want to start in the "active" state when you're running MPF with the virtual platform interfaces.

The reason these only work with the virtual platforms is because if you're running MPF while connected to a physical pinball machine, it doesn't really make sense to tell MPF which switches are active since MPF can read the actual switches from the physical machine. So you can add this section to your config file, but MPF only reads this section when you're running with one of the virtual hardware interfaces. To use it, simply add the section along with a list of the switches you want to start active. For example:

#! switches:
#!   s_trough_enter:
#!     number: 2
virtual_platform_start_active_switches: s_trough_enter

Here's the complete config

switches:
  s_drain:
    number: 01
  s_trough_enter:
    number: 02
  s_plunger:
    number: 10
coils:
  c_drain_eject:
    number: 03
    default_pulse_ms: 20
  c_trough_release:
    number: 04
    default_pulse_ms: 20
ball_devices:
  bd_drain:
    ball_switches: s_drain
    eject_coil: c_drain_eject
    eject_targets: bd_trough
    tags: drain
    eject_timeouts: 4s
  bd_trough:
    entrance_switch: s_trough_enter
    entrance_switch_full_timeout: 500ms
    ball_capacity: 3
    eject_coil: c_trough_release
    eject_targets: bd_plunger
    tags: trough, home
    eject_timeouts: 3s
  bd_plunger:
    ball_switches: s_plunger
    mechanical_eject: true
    eject_timeouts: 5s
playfields:
  playfield:
    default_source_device: bd_plunger
    tags: default
machine:
  balls_installed: 4
virtual_platform_start_active_switches: s_trough_enter

What if it doesn't work?

Have a look at our troubleshooting guide for ball_devices.


Something missing or wrong? You can fix it!

This website is edited by people like you! Is something wrong or missing? Is something out of date, or can you explain it better?

Please help us! You can fix it yourself and be an official "open source" contributor!

It's easy! See our Beginner's guide to editing the docs.

Page navigation via the keyboard: < >

You can navigate this site via the keyboard. There are two modes:

General navigation, when search is not focused:

  • F , S , / : open search dialog
  • P , , : go to previous page
  • N , . : go to next page

While using the search function:

  • Down , Up : select next / previous result
  • Esc , Tab : close search
  • Enter : go to highlighted page in the results